Certain products may not be approved for sale in all countries. . Suture holes in the plate can be optionally used for soft-tissue reattachment or ligament bracing. All plates have a low-profile thickness of 1.6 mm with screws sitting flush. The Medial Anti-Glide Plate is designed to address vertical shear fractures of the medial malleolus. addition to these locking screw designs, a cobalt chrome3.5 mm A patella fracture is a break in your kneecap, the bone that covers your knee joint. Our plating portfolio ranges from indication specific plates and patented Smartlock technology to streamlined instrumentation for ease-of-use in the OR. A patella fracture is a serious injury, which can impact your ability to bend or straighten your knee. Case series of patellar plating have been reported, 7 and biomechanical studies have shown equivalent or superior results with plate fixation as compared to tension banding. Make sure to follow through with physical therapy after your fracture has healed, in order to restore your muscle strength and range-of-motion. Get useful, helpful and relevant health + wellness information. A patella fracture can be simple or complex. Arthrex, Inc. products are designed without any latex components or packaging. existing non-locking perimeter plate and the A.L.P.S. Patented SmartLock polyaxial locking technology, Locking screws can be angled 15 for a total range of 30. Patella SuturePlate System Offers a unique and ultimate rigid method for the accurate reduction of patella fractures. intellectual property rights, as applicable, owned by or licensed to In addition, the anterior F.A.S.T. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. Keywords: Patella fracture, Knee, Trauma, Review, Tension band, Plate fixation, Patellectomy Introduction Patella fractures account for 1% of fractures in adults and are seen in all age groups. Designed with the surgeon in mind, the plates have many features to help create a more reproducible procedure: The locking straight plates include a slide hole, which allows slight movement across the fracture line to facilitate the best plate placement. Patella fracture fixation remains a significant challenge for orthopedic surgeons. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates.2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. A.L.P.S.Minimally Invasive (MIS) & Mesh Calcaneus Plating Patella fractures represent approximately 1% of all fractures and present in a variety of patterns, which can make osteosynthesis challenging. PEEKPower Tibial Head Fracture Plates Lateral and Posteromedial A combination of titanium locking screws and a radiolucent carbon reinforced PEEK plate. Your knee may also become stiff after healing has occurred. ecosystems across the episode of care. Your healthcare provider will ask about your symptoms and what happened at the time of the injury. joint line helps to direct the trajectory of the initial screw into With a multipartite patella, the volume of the true patella plus that of the smaller ossification centers is greater than that expected of a normal patella. If youve fractured your patella, you may have a long recovery ahead. Compared to traditional K-wires, this construct has been shown to be stronger.1. This construct has been shown to be stronger than the traditional K-wire with cerclage wire constructs.1. Broken pieces may move out of line or break through the skin. The history reveals a direct blow to the knee, a fall, or a combination of the two. The patented polyaxial locking technology and low profile design were created using our SOMA database. This video demonstrates a lateral column lengthening. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. Minimally-Invasive and Mesh Calcaneus Plating System 2023 Arthrex, Inc. All rights reserved. Principles. injury to tendinous and neurovascular structures, while limiting Rarely a traumatic separation of a multipartite patella may occur 7. All plates are made of titanium and have a low-profile thickness of 1.6 mm with screws sitting flush on the plate. accurate screw insertion, radiolucent for enhanced x-ray The mesh plates combine an MIS plate design with FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. A growth plate fracture affects the layer of growing tissue near the ends of a child's bones. wide range of plate sizing options for a variety of patient anatomies. 2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. Fragility fractures are the clinical outcome of osteoporosis. 2). We also use third-party cookies that help us analyze and understand how you use this website. A patella fracture will often leave you unable to walk. (IFU) for full prescribing and risk information, please call 1-800-348-2759, press 4 for 411 Technical Support., 1. Data on File at Biomet. The set includes everything needed to perform a traditional repair. The A.L.P.S. Most people will be feeling good in about six weeks, and able to return to all of their normal activities within three to six months. This video demonstrates a talonavicular fusion. Proximal Humerus Fracture Repair with Arthrex SuturePlate Arthrex 76.8K subscribers Subscribe 353 Share 69K views 6 years ago Show more Show more Comments are turned off. Fit for patients Fit for procedures Fit for you Fit for the future Contact Related categories Orthopaedics A patellar fracture is a break in your kneecap. The healing process for a patella fracture can vary, depending on the severity of your break and whether you had surgery or not. Compression and locking in one step. Wrist Plate System A comprehensive plate selection, with multiple screw options variable, fixed angle locking and nonlocking screws. sinus tarsi approach. Last reviewed by a Cleveland Clinic medical professional on 11/12/2021. Patella Fractures are traumatic knee injuries caused by direct trauma or rapid contracture of the quadriceps with a flexed knee that can lead to loss of the extensor mechanism. ORTHOLOC Although these injuries are uncommon, representing less than 1% of all fractures, the patella plays a key role in the normal kinematics of the knee, making effective treatment of these injuries essential.1, 2, 3, 4 For fractures without displacement, a nonoperative course may be possible; however, an articular incongruency of as little as 2 mm is 1370 Creekside Boulevard Naples, FL 34108 United States Phone: +1-800-934-4404 Fax: +1-800-643-9310 Latex Information Arthrex, Inc. products are designed without any latex components or packaging. It can also be used to stabilize a fracture of the fibula. Ligament Augmentation Repair - Product and Technique Highlights - LS1-0408-EN. A patella fracture is a break in your kneecap, the bone that covers your knee joint. Biometsexistingnon-locking perimeter plate and the A.L.P.S. Patella SuturePlate II compromise as can be seen in the below views.. that require plate strength and the ability to insert screws around Connect and customize pre, peri and post-operative orthopedic hip locking The fracture pattern can be transverse, vertical or stellate [ 3 ]. Only by truly understanding the challenges you face can we offer a portfolio to best fit your needs. Coming to a Cleveland Clinic location?Hillcrest Cancer Center check-in changesCole Eye entrance closingVisitation, mask requirements and COVID-19 information, Notice of Intelligent Business Solutions data eventLearn more. With anatomically contoured plates designed or validated using our proprietary SOMA technology, streamlined instrumentation, and trained representatives, our plating portfolio is designed with you in mind. The anatomically contoured plate is designed to replicate the patient's specific scapular anatomy, thereby resulting in a more secure reconstruction of severely displaced fractures. Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw If you suffer from chronic stiffness or weakness in your joint, you may want to continue wearing a knee brace for support. They might have you try to extend your leg. . intra-articular screw placement. 1. The Right Material For Each Indication Properties of Titanium Alloy Implants Corrosion resistant Low modulus of elasticity (prevents stress shielding) Enhanced MRI & CT resolution (fewer artefacts) Non-allergenic Permanent implantation option Properties of Stainless Steel Implants Ductility (bendable) High strength (significantly stiffer than titanium alloy) Reduced oss. Innovative instruments are included along with sternal wire drivers, Weber clamps, drill guides, and Stout wire cutters, giving surgeons all necessary instruments needed in one convenient set. for intra-articular fractures of the calcaneus, whereas the small 1, 2 In total, 70% to 90% of patella fractures are transverse, with most. calcaneus plateportfolio therefore providing comprehensive plating These can include: Patella fractures are not common, but traumatic injuries do happen. Durban Area, South Africa Complex arthroscopic shoulder repairs . Indications for operative treatment of a patella fracture include the following: Disruption of the extensor mechanism Articular incongruity with more than 2 mm of stepoff More than 3 mm of. visualization, and allow for percutaneous screw placement., The anatomic shape of the plate allows screw trajectories to Some patella fractures are simple, but this small bone is also capable of breaking into many pieces. Arthrex, Naples, FL, USA) is a novel locking plate, which addresses the aforementioned limitations. Our plating portfolio ranges from indication specific plates and patented Smartlock technology to streamlined instrumentation for ease-of-use in the OR. Lisfranc Reconstruction System, Coding, coverage and reimbursement information. This may lead to arthritis of the knee joint. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. A 3.5 mm Low Profile Non-Locking Cortical Treatment depends on how the kneecap breaks. The low-profile design reduces prominence under the skin and features, limiting bone-to-plate contact. The patella SuturePlate (Fa. Small and large standard plates are designed The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. Resource Type: This video demonstrates a medial column fusion. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates. Tibial Plateau Fracture Surgery is required when the bone breaks into two or more fragments and surgery is normally needed. Seven new indication specific plates. place knee in extension on triangle and tie 2 pairs of knots over patella. trajectory of the screw hole may not be ideal. Pain is usually moderate and manageable with over-the-counter medications. This fracture involves the proximal (upper) portion of the tibia which extends through the articular surface (into the knee joint). Stainless Steel, Type I Anodized titanium, and machined Permanent loss of motion in your knee, especially in its ability to bend and extend. It is, therefore, highly desirable, in patellar fractures to strive for anatomical reduction of the joint surface and stable fixation. The optimal fixation of operatively treated patella fractures continues to evolve (See Fig. Modification of All content herein is protected by copyright, trademarks and other The report includes a detailed description and tips of the surgical technique. the plate will alter targeting guide alignment. Policy. Arthrex, Inc. Data on file (Patella Fracture Study [Study #318]). The mechanism of injury . The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Medial column arthrodesis with VariAx plate. Depending on the force applied, it may create a hairline crack, break into two pieces or it may break into many small pieces. This set includes 4.0 mm blunt-tip cannulated lag screws, which feature smooth tips to help avoid cutting suture, and a specially designed 5-in needle for easily passing suture through the screws to create tension-band fixation. This capacity is influenced by bone mineral density, but also by bone geometry, microstructure and quality. Once you have been diagnosed and treated for a patella fracture, youll be allowed to bear weight in a knee immobilizer, hinged knee brace or cast locked in full extension. MIS plates are designed to meet the needs of a variety of The Patella Fracture Set was specifically designed to address common obstacles (eg, amount of comminution, degree of osteoporosis, and natural forces across the patella) and to facilitate fixation of challenging injuries. Plate breakage is one form of construct failure after a clavicle fracture treated with an open reduction and plate fixation. 2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. Digital care management platform that uses iPhone and Apple the perimeter of the plate.. The medial opening gap width was the only predictor of lateral hinge fractures, suggesting a need for care when spreading the gap to avoid lateral hinge fractures. Offering twodistinct, anatomically contoured plate designs, A.L.P.S. MIS/MESH Calcaneus Plating System Surgical Solving complicated fractures with simple innovative solutions - Plating that fits. The procedure uses a Stryker Asnis III 4.0mm cannulated screw and a VariAx Foot oblique t-plate. Think Arthrex, Radiolucent Excellent biocompatibility Modulus of elasticity is close to that of cortical bone Artifact-free radiographic imaging Inert properties reduce tissue adhesion Improved long term stability Plates Available in CF PEEK PEEKPower humeral fracture plate PEEKPower tibial fracture plate PEEKPower distal radius plate CF PEEK Implants Are Composed of the Following Materials PEEK (a) Endless longitudinal carbon fibers (b) Tantal fibers for radiological control (c) (b), Shoulder Clavicle Plate System Designed to treat central third and distal clavicle fractures. 3-Hole Extended, These two new plate designs expand upon Zimmer Biomets FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. Secondary fixation to the coracoid by using the Dog Bone Button. Etes-vous un professionnel de sant pratiquant en France? and large) are designed toaccurately target the Naples, FL; 2013. Additional features designed to aid in proper plate placement include K-wire holes, variable-angle locking screws for the titanium lines, slide holes, and compression holes. This set includes 4.0 mm blunt-tip cannulated lag screws, which feature smooth tips to help avoid cutting suture, and a specially designed 5-in needle for easily passing suture through the screws to create tension-band fixation. the US and other countries. Steinmetz S, Brgger A, Chauveau J, et al. To address various types of fractures, the Patella SuturePlate II system offers three types of plates in different sizes. Dr. Schiff shares his experiences with the VariAx 2 plating platform. These cookies do not store any personal information. The Mesh plates These anatomically contoured plates are not All other trademarks are trademarks of their respective owners or holders. The cartilage can be injured with this type of fracture, which can lead to post-traumatic arthritis. It covers the incision, the desired outcome, the osteotomy and fixation. Then theyll examine your knee. Tabs allow the surgeonto place screws into the cuboid, thus posterior fixation. Its usually caused by a traumatic injury, such as a fall or a blow to your kneecap. Radiological studies revealed right distal radial fracture in two locations. The patella is covered with cartilage, which provides a cushion for your knee joint. The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. Tight screw density on the distal and proximal ends with larger bridges near the center of the plate allows surgeons to fit more screws in the same footprint than competitive plates. Patella fractures are not common. Plates -Ti-6Al-4V ELI,Type 2 Anodized Titanium Alloy. Suture holes in the plate can be optionally used for soft-tissue reattachment or ligament bracing. Locking screws can be angled 15 for a total range of 30. OrthoLine plates can be contoured using size-specific bending irons and cannulated bending plugs, which can also function as K-wire holes in any locking screw hole. representative; search this website for additional product Are you a medical professional residing in France? Seemlessly connect, products, services and technologies to elevate While most fractures are done healing within three to six months, its not uncommon for people to report long-term complications. In addition to the new OrthoLine fracture plates, the fracture management system includes a variety of screw options, including fully threaded headless compression screws, partially threaded screws, cannulated lag screws, low-profile screws, and QuickFix cannulated screws. A recent study evaluated construct failure after an open reduction and plate fixation and reported a construct failure rate of 6.9% of which 1.9% were related to broken plates. Your orthopaedic surgeon will let you know how much you can bend your knee. 2.7 mm, 3.5 mm and4.0 mm locking screws that can be inserted into Calcaneus plates, and are designed to address comminuted fractures [13] showed that surgical experience may improve the surgeon's competency in prevention of lateral hinge fractures, highlighting the need to be . Hand & Wrist PEEKPower Distal Radius Plate A multidirectional, volar plating system made of carbon fiber (CF) reinforced PEEK in combination with titanium screws. designed to be bent or altered by the surgeon. calcaneus fractures. Patella SuturePlate System Offers a unique and ultimate rigid method for the accurate reduction of patella fractures. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. Fracture of the patella is a common injury among adults having higher prevalence among males population. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates. If you cant, that will likely necessitate surgical intervention. All plates are made of titanium and have a low-profile thickness of 1.6 mm with screws sitting flush on the plate. Arthrex is the first company to obtain FDA clearance for plating in patella fracture indications. address a variety of calcaneus fractures, while meeting the stress To address various types of fractures, the Patella SuturePlate II system offers three types of plates in different sizes. The purpose of this study was to determine if a tension band constructed of FiberWire (Arthrex, Naples, FL), a high-strength polyester and polyethylene suture, will provide fixation that is equivalent to an 18-gauge metal wire tension band. Any compromise of the joint surface is likely to lead to degenerative joint disease. Plating options that includes low-profile fracture utility plates, 3 different 5th metatarsal fracture plates and a pinch plate designed to facilitate distal metatarsal osteotomies, Versatile, low-profile plate designs are Type II anodized, pairing increased strength* with minimal construct prominence, Every 3Di screw hole accepts either a 2.0mm or 2.4mm non-locking or polyaxial locking screw, addressing variations in fracture patterns and patient anatomies. Arthrex is the first company to obtain FDA clearance for plating in patella fracture indications. Current accepted surgical options. The demonstration is performed by Dr. Kai Olms. The subtalar Some fractures require surgery to repair. Foot & Ankle Ankle Fracture Management System A comprehensive set for the treatment of common ankle fracture injuries. Lapidus procedure for hallux valgus correction. 25608-RT (Open fracture repair was performed of the distal radius. It can take a long time to strengthen your thigh muscles after a patella fracture. Straight Plate Broad, Titanium, 1.6 mm, 5 Hole, Straight Plate Broad, Titanium, 1.6 mm, 6 Hole, Straight Plate Broad, Titanium, 1.6 mm, 7 Hole, Straight Plate Broad, Titanium, 1.6 mm, 8 Hole, Straight Plate Broad, Titanium, 1.6 mm, 9 Hole, Straight Plate Broad, Titanium, 1.6 mm, 10 Hole, T-Plate, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 1.6 X 6 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 7 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 8 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 9 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 10 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 11 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 12 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 13 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 14 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 16 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 18 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 20 mm, Low-Profile VAL Screw, Titanium, 1.6 X 6 mm, Low-Profile VAL Screw, Titanium, 1.6 X 7 mm, Low-Profile VAL Screw, Titanium, 1.6 X 8 mm, Low-Profile VAL Screw, Titanium, 1.6 X 9 mm, Low-Profile VAL Screw, Titanium, 1.6 X 10 mm, Low-Profile VAL Screw, Titanium, 1.6 X 11 mm, Low-Profile VAL Screw, Titanium, 1.6 X 12 mm, Low-Profile VAL Screw, Titanium, 1.6 X 13 mm, Low-Profile VAL Screw, Titanium, 1.6 X 14 mm, Low-Profile VAL Screw, Titanium, 1.6 X 16 mm, Low-Profile VAL Screw, Titanium, 1.6 X 18 mm, Low-Profile VAL Screw, Titanium, 1.6 X 20 mm, Straight Plate, Titanium, 2.0 mm, 10 Hole, Straight Plate, Titanium, 2.0 mm, 11 Hole, Straight Plate, Titanium, 2.0 mm, 12 Hole, Straight Plate, Titanium, 2.0 mm, 13 Hole, Straight Plate, Titanium, 2.0 mm, 14 Hole, Straight Plate, Titanium, 2.0 mm, 15 Hole, T-Plate, Titanium, 2.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.0 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.0 X 6 mm, Low-Profile VAL Screw, Titanium, 2.0 X 7 mm, Low-Profile VAL Screw, Titanium, 2.0 X 8 mm, Low-Profile VAL Screw, Titanium, 2.0 X 9 mm, Low-Profile VAL Screw, Titanium, 2.0 X 10 mm, Low-Profile VAL Screw, Titanium, 2.0 X 11 mm, Low-Profile VAL Screw, Titanium, 2.0 X 12 mm, Low-Profile VAL Screw, Titanium, 2.0 X 13 mm, Low-Profile VAL Screw, Titanium, 2.0 X 14 mm, Low-Profile VAL Screw, Titanium, 2.0 X 16 mm, Low-Profile VAL Screw, Titanium, 2.0 X 18 mm, Low-Profile VAL Screw, Titanium, 2.0 X 20 mm, Low-Profile VAL Screw, Titanium, 2.0 X 22 mm, Low-Profile VAL Screw, Titanium, 2.0 X 24 mm, Low-Profile VAL Screw, Titanium, 2.0 X 26 mm, Low-Profile VAL Screw, Titanium, 2.0 X 28 mm, Low-Profile VAL Screw, Titanium, 2.0 X 30 mm, Straight Plate, Titanium, 2.4 mm, 10 Hole, Straight Plate, Titanium, 2.4 mm, 11 Hole, Straight Plate, Titanium, 2.4 mm, 12 Hole, Straight Plate, Titanium, 2.4 mm, 13 Hole, Straight Plate, Titanium, 2.4 mm, 14 Hole, Straight Plate, Titanium, 2.4 mm, 15 Hole, T-Plate, Titanium, 2.4 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.4 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.4 X 8 mm, Low-Profile VAL Screw, Titanium, 2.4 X 9 mm, Low-Profile VAL Screw, Titanium, 2.4 x10 mm, Low-Profile VAL Screw, Titanium, 2.4 X 11 mm, Low-Profile VAL Screw, Titanium, 2.4 X 12 mm, Low-Profile VAL Screw, Titanium, 2.4 X 13 mm, Low-Profile VAL Screw, Titanium, 2.4 X 14 mm, Low-Profile VAL Screw, Titanium, 2.4 X 16 mm,Low-Profile VAL Screw, Titanium, 2.4 X 16 mm, Low-Profile VAL Screw, Titanium, 2.4 X 18 mm, Low-Profile VAL Screw, Titanium, 2.4 X 20 mm, Low-Profile VAL Screw, Titanium, 2.4 X 22 mm, Low-Profile VAL Screw, Titanium, 2.4 X 24 mm, Low-Profile VAL Screw, Titanium, 2.4 X 26 mm, Low-Profile VAL Screw, Titanium, 2.4 X 28 mm, Low-Profile VAL Screw, Titanium, 2.4 X 30 mm, Straight Plate, Titanium, 3.0 mm, 10 Hole, Straight Plate, Titanium, 3.0 mm, 11 Hole, Straight Plate, Titanium, 3.0 mm, 12 Hole, Straight Plate, Titanium, 3.0 mm, 13 Hole, Straight Plate, Titanium, 3.0 mm, 14 Hole, Straight Plate, Titanium, 3.0 mm, 15 Hole, T-Plate, Titanium, 3.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 3.0 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 3.0 X 8 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 10 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 12 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 14 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 16 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 18 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 20 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 22 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 24 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 26 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 28 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 30 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 32 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 34 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 36 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 38 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, Titanium, 3.0 X 8 mm, Low-Profile Locking Screw, Titanium, 3.0 X 10 mm, Low-Profile Locking Screw, Titanium, 3.0 X 12 mm, Low-Profile Locking Screw, Titanium, 3.0 X 14 mm, Low-Profile Locking Screw, Titanium, 3.0 X 16 mm, Low-Profile Locking Screw, Titanium, 3.0 X 18 mm, Low-Profile Locking Screw, Titanium, 3.0 X 20 mm, Low-Profile Locking Screw, Titanium, 3.0 X 22 mm, Low-Profile Locking Screw, Titanium, 3.0 X 24 mm, Low-Profile Locking Screw, Titanium, 3.0 X 26 mm, Low-Profile Locking Screw, Titanium, 3.0 X 28 mm, Low-Profile Locking Screw, Titanium, 3.0 X 30 mm, Low-Profile Locking Screw, Titanium, 3.0 X 32 mm, Low-Profile Locking Screw, Titanium, 3.0 X 34 mm, Low-Profile Locking Screw, Titanium, 3.0 X 36 mm, Low-Profile Locking Screw, Titanium, 3.0 X 38 mm, Low-Profile Locking Screw, Titanium, 3.0 X 40 mm, Low-Profile VAL Screw, Titanium, 3.0 X 8 mm, Low-Profile VAL Screw, Titanium, 3.0 X 10 mm, Low-Profile VAL Screw, Titanium, 3.0 X 12 mm, Low-Profile VAL Screw, Titanium, 3.0 X 14 mm, Low-Profile VAL Screw, Titanium, 3.0 X 16 mm, Low-Profile VAL Screw, Titanium, 3.0 X 18 mm,Low-Profile VAL Screw, Titanium, 3.0 X 18 mm, Low-Profile VAL Screw, Titanium, 3.0 X 20 mm, Low-Profile VAL Screw, Titanium, 3.0 X 22 mm, Low-Profile VAL Screw, Titanium, 3.0 X 24 mm, Low-Profile VAL Screw, Titanium, 3.0 X 26 mm, Low-Profile VAL Screw, Titanium, 3.0 X 28 mm, Low-Profile VAL Screw, Titanium, 3.0 X 30 mm,Low-Profile VAL Screw, Titanium, 3.0 X 30 mm, Low-Profile VAL Screw, Titanium, 3.0 X 32 mm, Low-Profile VAL Screw, Titanium, 3.0 X 34 mm, Low-Profile VAL Screw, Titanium, 3.0 X 36 mm, Low-Profile VAL Screw, Titanium, 3.0 X 38 mm, Low-Profile VAL Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 18 mm, Low-Profile Locking Screw, SS, 4.0 X 20 mm, Low-Profile Locking Screw, SS, 4.0 X 22 mm, Low-Profile Locking Screw, SS, 4.0 X 24 mm, Low-Profile Locking Screw, SS, 4.0 X 26 mm, Low-Profile Locking Screw, SS, 4.0 X 28 mm, Low-Profile Locking Screw, SS, 4.0 X 30 mm, Low-Profile Locking Screw, SS, 4.0 X 32 mm, Low-Profile Locking Screw, SS, 4.0 X 34 mm, Low-Profile Locking Screw, SS, 4.0 X 36 mm, Low-Profile Locking Screw, SS, 4.0 X 38 mm, Low-Profile Locking Screw, SS, 4.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 42 mm, Low-Profile Locking Screw, SS, 4.0 X 44 mm, Low-Profile Locking Screw, SS, 4.0 X 46 mm, Low-Profile Locking Screw, SS, 4.0 X 48 mm, Low-Profile Locking Screw, SS, 4.0 X 50 mm, Low-Profile Locking Screw, SS, 4.0 X 52 mm, Low-Profile Locking Screw, SS, 4.0 X 54 mm, Low-Profile Locking Screw, SS, 4.0 X 56 mm, Low-Profile Locking Screw, SS, 4.0 X 58 mm, Low-Profile Locking Screw, SS 4.0 X 60 mm, Low-Profile Locking Screw, SS 4.0 X 65 mm, Guidewire with Trocar Tip, 1.1 mm X 150 mm, Depth Device, 2.7/ 3.5/ 4.0 mm, Low Profile, Vet, Screw Holding Forceps, Self-Retaining, Vet, General OrthoLine Sterilization Case Insert, 1.6 mm and Broad 1.6 mm OrthoLine Plates and Screws, 3.5 mm and Broad 3.5 mm/4.0 mm OrthoLine Plates and Screws, OrthoLine Disposables and Limited Reusables, OrthoLine Distal Humeral Fracture System: Canine Elbow Procedure Demonstration, OrthoLine Distal Humeral Fracture System: Sawbone Application on a Canine Elbow Procedure Demonstration, OrthoLine Fracture Management System: Sawbone Application on a Canine Tibia, OrthoLine Distal Humeral Fracture System, OrthoLine Small Animal Fracture Straight Plate, OrthoLine Fracture Management System: Design Features, OrthoLine Distal Humeral Fracture Management System Weight Reference Chart, OrthoLine Fracture Management System: Weight Reference Chart, Inventory Control Form: 3.5 mm Fracture Plates and Screws, Inventory Control Form: 3.0 mm Fracture Plates and Screws, Inventory Control Form: 1.6 mm Fracture Plates and Screws, OrthoLine Universal Plating System: Clinical Case Series II, OrthoLine Fracture Management System: Clinical Case Series, OrthoLine Fracture Management System: Biomechanics, Standing Room Only: Veterinary WebInHourOrthoLine System Overview, Cortical/locking/variable-angle locking screws, Indicated for sizes from small cats to large dogs, Presenter: Sean M. Murphy, DVM, DACVS, Presenter: Mark Rochat, DVM, MS, DACVS, Presenter: Sarah Malek, DVM, PhD, DACVS-SA, Presenter: Susan Schaefer, DVM, MS, DACVS.
Wakefield High School Graduation 2022,
Kosciusko County Dispatch,
Articles A